Instructions for using imported high temperature ultrasonic flowmeter

Since entering China, FLEXIM FLUXUS imported brands have obvious advantages in the field of fluid flow measurement, especially imported high-temperature ultrasonic flowmeters and gas ultrasonic flowmeters in some industries in China. However, in the use of ultrasonic flowmeters, especially when measuring high-temperature heat-conducting oils, it is necessary to remind the FLEXIM FLUXUS users that they should follow the instructions of our imported FLEXIM FLUXUS imported ultrasonic flowmeters step by step.
FLEXIM imported series of ultrasonic flowmeters are divided into normal temperature type and high temperature type. When measuring temperatures above 200 degrees, high temperature ultrasonic flow probes must be used. Don't exceed the limit of several times because you believe in German quality. When the temperature of the pipeline medium exceeds 300 degrees, you must use high temperature waveguide plate and use the high temperature probe of imported ultrasonic flowmeter. Our technicians I often visit, train and communicate with major institutions in China. The purpose is to let the customers of FLEXIM FLUXUS imported series ultrasonic flowmeters use peace of mind and worry. But the feedback received is still worrying.
It is important to emphasize and emphasize that when measuring the temperature of the medium is more than 300 degrees, it is necessary to use a high temperature probe and a wave guide plate (this combination can test the fluid with a medium temperature of 400 degrees or less). Don't be lucky enough to prevent unnecessary losses. A few days ago, our company received a damaged probe of a certain unit, because it was testing the liquid medium of about 320 degrees. In order to save trouble, without the high-temperature waveguide board, the high-temperature probe was used to directly cover the outer wall of the pipeline for nearly 2 hours. Causes the ultrasonic flowmeter probe to explode and damage.
At the same time, the company's sales staff is required to make the application plan for potential customers. It is necessary to clarify the user's needs and application conditions, and make a practical configuration plan. The customer's "expensive" word can not be reduced. If it is really necessary, the reduction is required. The user must be clearly told that the solution is suitable for measuring the temperature of the medium within 200 degrees, within 300 degrees, or within 400 degrees. And signed a technical agreement with the customer as the basis for future contract execution and follow-up services. Eliminate quotations and programs that do not pay responsibility.

Freeze Dryer/lyophilizer is widely used in medicine, pharmaceuticals, biological research, chemical industry and food and other fields. The freeze-dried articles are easy to preserve for a long time. After adding water, they can be restored to the pre freeze state and retain their original biochemical characteristics.


  • Application scope

It is suitable for freeze-drying of conventional substances in bulk (liquid, paste, solid).


  • Product classification
Laboratory Vacuum Freeze Dryer

Pilot type Vacuum Freeze Dryer

Medical Vacuum Freeze Dryer

Food type vacuum Freeze Dryer

Large scale universal vacuum freeze dryer



Freeze dryer




Laboratory freeze dryer



Vacuum freeze dryer



Food freeze dryer



Food freeze dryer

Freeze Dryer/lyophilizer

Freeze Dryer/lyophilizer,Freeze Dryer,Vacuum Freeze Dryer,Vacuum Lyophilizer

Zhengzhou mingyi instrument equipment co.,ltd , http://www.mingyint.com