1) Routine inspections are conducted systematically based on the equipment's operation and customer requirements to ensure smooth performance and long-term reliability.
2) To maximize the efficiency of the evaporative cooling unit, it is essential to operate the product under the following conditions:
a) Ambient temperature: 18°C to 45°C. b) Relative humidity: ≤ 85%. c) Atmospheric pressure: 86 kPa to 106 kPa. d) Water supply must be softened, with a temperature not exceeding 45°C and a pressure between 0.15–0.6 MPa. e) Voltage deviation should not exceed ±10% of the rated voltage. f) The ambient air quality must meet or exceed GB 3096 Level 3 standards. g) Avoid corrosive environments.
3) This product is flammable. Keep it away from any open flames during transportation, installation, and operation to prevent fire hazards.
4) Before using the unit, make sure the inlet and drain pipes are properly connected. Failure to do so may lead to leaks that could damage other equipment or systems.
5) For optimal performance, ensure there are sufficient doors or windows open for airflow. If natural ventilation is inadequate, use blinds or install additional mechanical ventilation systems.
6) During operation, never disassemble critical components such as the evaporator or top cover. If maintenance or repair is needed, always disconnect the power first to avoid equipment damage or personal injury.
7) Inspect the motor’s condition during installation. Never use fuses or wires with incorrect ratings, as this can cause serious malfunctions.
8) In areas with high levels of airborne dust, consider installing a filter to improve air quality and extend the unit’s lifespan.
9) For locations with strict temperature and humidity control requirements, consult a qualified professional for guidance to ensure proper system integration.
10) If any abnormal behavior occurs during operation, contact the manufacturer or authorized service center immediately for assistance and repairs.
Preventive Maintenance Guidelines
1) Pre-season maintenance: Before the cooling season begins, inspect the unit’s perimeter and air intake area for obstructions or debris.
2) Daily maintenance: Regularly clean the unit’s chassis. Press the “Cleaning†button on the control panel daily to flush out water and prevent bacterial growth or unpleasant odors.
3) Cycle maintenance: After 1–2 months of operation, clean the unit if the wet curtain is dirty, the filter is clogged, or the surroundings are too dusty. Timely cleaning helps prevent malfunctions and ensures efficient operation.
4) End-of-season maintenance: To avoid freezing damage and mosquito breeding, turn off the water supply before long periods of inactivity. Then press the cleaning button to drain all water and disconnect the power.
5) Internal cleaning: If the unit runs continuously for extended periods, it should be thoroughly cleaned every 1–2 months. Refer to the user manual for detailed instructions on disassembling and cleaning the internal components.