Concrete pump hydraulic system heating reasons

1. Introduction From the investigation of the use of concrete pump found that many types of concrete pump, the use of about 40min, the hydraulic system temperature up to 60e, after about 2h, the hydraulic system thermal equilibrium temperature can be as high as 70e above the concrete pump The normal thermal equilibrium temperature of the hydraulic system should be about 50e. Therefore, there has been a concrete pump hydraulic system, the problem of excessive heating oil temperature problem. 2. Concrete pump hydraulic system heating phenomenon hazards concrete pump hydraulic system heating, a direct impact on the normal operation of concrete pumps, fever caused by the harm, mainly in the following points: (1) working fluid temperature increases, so that work Liquid viscosity decreases, pump leakage increases, the actual flow of the pump decreased; (2) the hydraulic system and components of the seals metamorphism at high temperatures, elastic degeneration ability to reduce the sealing performance, or seal failure, so that leakage increased ; (3) When the hydraulic valve parts of the valve body, valve body material, different thermal expansion coefficient, the valve core, the valve body due to thermal expansion valve stuck, resulting in the concrete pump can not work; (4) working fluid Of the viscosity decreases, the working fluid lubrication performance decreases, hydraulic components wear and tear accelerated, accelerated wear and tear components failure, shorten the life of the components. In order to avoid the occurrence of the above phenomena, some concrete pumps have to stop after being used for a certain period of time to cool down the system, thereby reducing the startup rate of concrete pumps and affecting the construction progress. Therefore, we should take into account the causes of system heat, take appropriate measures to control the temperature of the hydraulic system to ensure the normal use of concrete pumps. 3. Concrete pump hydraulic system heating the main reasons and troubleshooting Hydraulic system heating by heating can be divided into two categories: one is due to the design of the cause of fever; one is due to hydraulic components or improper use of the reasons , Caused by fever. Obviously, different causes of fever, the exclusion method is not the same. 3.1 unreasonable design, resulting in the heating of the hydraulic system and its exclusion (1) improper selection of hydraulic oil number may cause heating of the hydraulic system The selected hydraulic oil in the oil temperature is low, the system works normally, but the system for a period of time After the oil temperature increases, the viscosity of hydraulic oil decreases, resulting in increased internal system leakage, with the increase of leakage also led to an increase in oil temperature, the formation of a vicious cycle of oil temperature. The solution is: According to the system load and normal operating temperature requirements, select the appropriate viscosity of the hydraulic oil. (2) The fuel tank design is unreasonable, and the heat dissipation effect of the hydraulic system is reduced. The main function of the system heating oil tank is to store hydraulic oil, but it also has the functions of dissipating heat, precipitating impurities and separating water. Fuel tank design is unreasonable, mainly in two aspects: First, the fuel tank volume design is too small, because the concrete pump is a mobile hydraulic equipment, the fuel tank volume is generally about double the hydraulic pump, so the tank cooling area and oil reserves Second, some of the tanks in the structural design is not reasonable, the suction nozzle and the return pipe port closer, no separator in the middle, thus shortening the oil in the tank cooling cycle and the path of precipitation of impurities, or even Resulting in most of the return oil directly into the suction pipe, reducing the cooling effect of the fuel tank, increasing the oil temperature. The solution is to increase the tank volume appropriately to make the tank volume (1125 ~ 115) Q, and try hard to increase the distance between the suction pipe mouth and the oil return pipe mouth. The partition plate should be set between the suction pipe and the oil return pipe to ensure that the fuel tank Should have cooling power. (3) smaller heat flux, cooler installation location is unreasonable, so that the cooling capacity of the system reduces the cooling capacity of concrete pumps are air-cooled and water-cooled two, users can choose according to the actual situation, but the general use of air-cooled more. Some concrete pumps consider the pressure requirements of the cooler, the cooler is set on the oil return line of the stirring system, and only the oil of the stirring system is cooled. Due to the smaller flow rate of the stirring system, the cooling effect of the entire system is poor, fever. Solution: First, an independent cooling circuit can be used to improve the cooling effect. The second is to set the cooler in the system total oil return to increase the heat flow, improve cooling effect, but this time should pay attention to two problems, the first issue is the cooling fan speed, cooling fan speed can not be too low, Otherwise it will reduce the cooling effect, you can use the motor to drive the fan, or in the total oil return road set a low-voltage drive motor, the motor speed and cooling flow to match, but also can solve the main circuit pressure impact on the cooler pressure capacity; The second problem is the use of motor-driven fan, the main system of the pressure impact on the cooler pressure capacity, this time, the return line and the cooler and installed a low pressure overflow protection valve or one-way valve for cooling The highest pressure protection device. (4) improper selection of hydraulic components, resulting in system heating concrete pump hydraulic system is generally high pressure flow system, if the system of hydraulic components, the main valve, relief valve and sequence valve size selection is not reasonable, can not meet the large Flow requirements, which in use, so that the flow velocity of the valve port flow is too high, resulting in greater pressure loss and the oil temperature, therefore, hydraulic system design in the selection of hydraulic components design, must be based on hydraulic components The maximum working pressure to be sustained, the maximum flow rate passed, and the required range of pressure and flow adjustment to minimize the pressure loss at the valve port and thereby reduce the heating of the system due to the unreasonable selection of hydraulic components. (5) pipeline design, installation unreasonable, resulting in large pressure loss, so that the pressure can be converted into heat energy in the hydraulic system design, piping design and installation can not be ignored, the pipeline diameter should be strictly according to their working pressure and through Flow design, to avoid too small diameter design, resulting in high flow velocity, along the pressure loss is too large, causing fever. At the same time, it should also pay attention to the installation of the pipeline, it is necessary to achieve the appearance of tidy, but also to avoid pipelines gather and the pipeline sharp turn, affecting the natural cooling pipe or cause local pressure loss caused by excessive heat. 3.2 due to improper use of hydraulic system or component failure, resulting in heating of the hydraulic system and its exclusion (1) the hydraulic oil tank surface below the minimum liquid surface, so that the tank cooling power reduction Concrete pump in use, to observe the tank at any time The height of oil level of hydraulic oil always keeps the height of hydraulic oil surface within the normal oil level so as to ensure the heat dissipation effect of the oil tank. When the hydraulic oil level inside the oil tank is lower than the minimum level, it is necessary to oil the oil tank in time. (2) Cooler cooling effect is reduced, so that the fluid temperature rise, cooling system cooler cooling effect may be caused by the following reasons: a1 cooler internal blockage or surface dirt more, causing the cooler safety device is turned on, the cooler Therefore, the concrete pump must be regularly checked in use, to clear the cooler, periodically on the cooler surface Dirt removal, to ensure smooth internal cooler and external cleaning, to ensure cooler cooling effect. b1 cooler relief valve or check valve opening pressure is lower than the standard value, so that the cooler safety protection device is open when the cooler is not blocked, resulting in overflow shunt, cooler cooling flow to reduce, therefore, the cooler before use , We must correctly adjust the opening pressure of the safety protection device, in the use of regular inspection to correct the safety protection device opening pressure value. (3) improper adjustment of the hydraulic system pressure, resulting in system heat In the concrete pump hydraulic system, due to the performance requirements, the system often have safety valves, relief valves and sequence valves. If the safety valve pressure is too low, the safety valve will be frequently opened, resulting in overflow loss, resulting in system fever; if the pressure is too high, it will increase the system leakage, the system fever, therefore, should be hydraulic system Load requirements, correct calculation and adjustment of safety valves and pressure values ​​to ensure that the system operates within the specified pressure range. When the main pump of the pump system is a closed system, the heat exchange circuit must be installed in the pumping system. The set pressure of the relief valve in the heat exchange circuit should be taken seriously. If the set pressure is too low, the pump hydraulic pressure Cylinder commutation increases, set the pressure is too high, will make the overflow loss is too large, the system temperature is too high. Therefore, we should reasonably determine the heat exchanger circuit relief valve adjustment pressure value, the general adjustment value of the relief valve (1 ~ 115) MPa, pumping system charge circuit working pressure of 215MPa. When the concrete pump hydraulic system When setting the sequence valve, we must understand the working characteristics of the sequence valve, the correct sequence valve working pressure. If the internal control sequence valve to adjust the pressure is too high, when the working pressure of the hydraulic cylinder is lower than the adjustment pressure, there is pressure loss of the sequence valve port, causing temperature rise, resulting in system fever, a reasonable set of internal control sequence valve settings Pressure, the working pressure of the working cylinder is higher than the opening pressure of the sequence valve. When the sequence valve is in operation, the valve port will be fully open and the valve port will be substantially pressure-free, thereby avoiding the system heat caused by the improper setting of the sequence valve . (4) The internal leakage increases, the oil temperature can be raised, the system heat concrete pump hydraulic system of internal leakage, including hydraulic pump, hydraulic cylinder, hydraulic motor and hydraulic valve internal leakage, pressure oil in the leakage process, the pressure drop, Temperature rises. If the system increases the internal leakage, will cause the oil temperature to rise, the system overheated, serious, it will make the system pressure drop, poor pumping, pumping displacement decreased, stirring weak, mixing speed decline. Therefore, regular inspection of these components, the replacement of the corresponding sealing components on a regular basis, the timely replacement of damaged or injured parts replacement or repair, or even replace the corresponding hydraulic components, so as to avoid component leakage caused by the system heat. Concrete pump hydraulic system fever in the course of the problem has become one of the problems can not be ignored, due to the heating of the hydraulic system, will lead to coagulation

Door Stops , Door Holders, Door Guards , Door Chains, Door Bolts , Door Coordinator, door viewers, etc are always required for whatever wooden or metal doors. We have been manufacturing a very big range of such small hardware accessories. The best seller is the half-round stopper in both stainless steel and zinc alloy. There could be of course, some accessories not shown in our web pages, as we have not updated every single product there.
Should you have any further demands, please feel free to contact us any time. And welcome for OEM products with detailed technical drawings.

Door Accessories

Door Stops,Door Holders,Door Guards,Door Chains

Greatwall Hardware International Limited , http://www.greatwall-hardware.com